Standard Survey Product
Three Axis Electric Field (EU, EV, EW) and Three Axis Magnetic field (BU, BV, BW) cross spectral matrix, 6 diagonal components and 15 off-diagonal components
| EU | EV | EW | BU | BV | BW |
EU | EUEU | EUEV | EUEW | - | - | - |
EV | - | EVEV | EVEW | - | - | - |
EW | - | - | EWEW | - | - | - |
BU | BUEU | BUEV | BUEW | BUBU | BUBV | BUBW |
BV | BVEU | BVEV | BVEW | - | BVBV | BVBW |
BW | BWEU | BWEV | BWEW | - | - | BWBW |
Units:
| EU | EV | EW | BU | BV | BW |
EU | V2/m2/Hz | V2/m2/Hz | V2/m2/Hz | - | - | - |
EV | - | V2/m2/Hz | V2/m2/Hz | - | - | - |
EW | - | - | V2/m2/Hz | - | - | - |
BU | nT V/m/Hz | nT V/m/Hz | nT V/m/Hz | nT2/Hz | nT2/Hz | nT2/Hz |
BV | nT V/m/Hz | nT V/m/Hz | nT V/m/Hz | - | nT2/Hz | nT2/Hz |
BW | nT V/m/Hz | nT V/m/Hz | nT V/m/Hz | - | - | nT2/Hz |
65 Frequency Bins
Frequency range: 10 kHz to 487kHz
Cadence: 1 spectra per second (when active) One spectra every 6 seconds will be skipped for the survey product.
File Description
File Name: rbsp-?_WFR-spectral-matrix_emfisis-L2_<YYYYmmdd>_<version>.cdf
Variables:
Epoch: TT2000 epoch, nanoseconds since 2000.
BuBu: Bu Autocorrelation
BvBv: Bv Autocorrelation
BwBw: Bw Autocorrelation
EuEu: Eu Autocorrelation
EvEv: Ev Autocorrelation
EwEw: Ew Autocorrelation
WFR_bins: Number of bins in the original FFT spectra that are summed together on board to produce the current frequency bin.
WFR_bandwidth: Bandwidth of each WFR bin.
WFR_frequencies: Center band frequency for each frequency bin. Frequencies are logarithmically spaced.
LWEzGainW: Attenuator select indicator for W axis. 0 – Off, 1 – On. Switches in a 19 dB attenuator. L2 and greater data has the attenuator gains folded into data to provide correct science units.
LWExEyGainUV: Attenuator select indicator for U and V axis. 0 – Off, 1 – On. Switches in a 19 dB attenuator. L2 and greater data has the attenuator gains folded into data to provide correct science units.
SCMBW: EFW Bandwidth limiter select indicator for MSC. 0 – Off, 1 – On. Switches in a 19 dB attenuator. L2 and greater data has the attenuator gains folded into data to provide correct science units.
SCMGain: Attenuator select indicator for MSC. 0 – Off, 1 – On. Switches in a 19 dB attenuator. L2 and greater data has the attenuator gains folded into data to provide correct science units.
SPTT: Sun Pulse time tag. Epoch of the last sun pulse.
APID: Data APID